Rating in Va : |
300Va. |
|
Rating in Watt. : |
225W. |
|
Nominal Input voltage. : |
220 + 10% V AC, Single Phase, 50 Hz.
|
|
Inverter Output Voltage : |
230 + 5% V AC. |
|
Output Frequency : |
50 Hz + 1%. |
|
Low Voltage Mains Cut Off : |
Yes. |
|
High Voltage Mains Cut Off : |
Yes. |
|
Overload Capacity : |
110% Cont., 300% for 30mS. |
|
Type of Battery Required. : |
Industrial / Tubular / SMF. |
|
No. of Battery Required. : |
01. |
|
Nominal Battery Voltage. : |
12V DC. |
|
Capacity of Battery in Ah. : |
100Ah to 200Ah as per your requirement. |
|
Type of Battery Charger. : |
Fully Automatic Multi Stage Phase Control Charger. |
|
PC Connectivity : |
Yes. |
|
LCD Display - Mains On Mode :
|
Mains Supply AC Voltage Meter & Frequency Meter on LCD Display. |
|
Battery Voltage DC Meter &
Charging Current in Amp. Meter on LCD Display. |
|
Make & Model Display. |
|
Battery Charging Percentage,
Battery Capacity in Ah & Battery Charged In Ah. on LCD Display. |
|
Battery is Charging or Battery is
Fully Charged on LCD Display. |
|
Special Function on Mains Mode: |
Display "Out-put Error" if Mains
voltage / Spikes are beyond controlled. |
|
LCD Display on Mains Fail Mode :
|
Inverter Mode Out-put Voltage Meter, Battery Voltage Meter,
Battery - Discharging Current Meter on LCD Display. |
|
Approx. Back-up Time in Hours & Min. on LCD Display. |
|
Make & Model Display. |
|
Battery Charging Percentage, Battery Capacity in
Ah & Battery Charged In Ah. on LCD Display. |
|
Inverter is Operating or Inverter is Switched Off. |
|
Inverter Shut-down Over Load or Battery Low. |
|
Load Level Indicator on Inv. Mode : |
Load usage in Watt Meter, Load usage in Percentage, Load usage
Graph on LCD Display. |
|
Special Function On
Inverter Mode : |
No Load Shutdown with
Auto Start as soon as higher Load is Switched On. (Preset able
only by Service Engineer) (Company Setting is in Off Mode)
|
|
Protection. : |
Over Load in Inverter mode, Battery deep Discharge,
Battery Over Charge, Short Circuit, High-Low Voltage Cut-Off. |
|
Audio Alarm : |
High Pitch Buzzer for Overload and Battery Low early Buzzer
with LCD Display, Mains Fail & Mains Re-Stored Signal Buzzer. |
|
Efficiency : |
95% Average.* |
|
Cost
in USD without Battery: |
USD
238/= |
|
Special Quantity Discount: |
Available. |
|
Sample
Quantity & Delivery Period: |
Minimum 1 Pc & Delivery Period Ex-Stock or 1 to 2 Weeks. |
|
Minimum Order Quantity: |
50Pcs
After Sample is Approved. |
|
Delivery
Period: |
Ex-Stock or 3 to 4
Weeks. |
|
Mode
of Delivery: |
Ex-Factory. |