SALIENT FEATURES OF  

GIRIRAJ INTELLIGENT UPS SYSTEMS :

 

            A UPS is primarily designed to protect you from system damage and data loss caused by power  failures, but a UPS can supply backup power to a computer for only a limited period of time.  If the system is not Shut-down  before  the  UPS batteries are exhausted, the system will crash. This is the same result as if there were no UPS present at all. We have successfully developed new Intelligent U.P.S. system with Power Management Software. This is a unique Monitoring System which automatically displays following Indications on your Computer.:

 

Mains Failure Window:

When Mains Supply Fail it gives indicator window on Your Computer for Mains Fail & Battery Back-up with Auto Shut-Down.

 

Mains Restored Window:

When Mains Supply Re-stored it gives Indicator window on Computer for Mains Re-stored & Shut-Down Canceled.

 

Remaining Back-up Time:

        At the time of Power Failure it gives you Display for Remaining Back-up Time on Computer, so that you can save your Data of Day End or Month End etc. and Shut-Down the Computer properly.

 

Auto Shut-Down Facility:

        If you do not Shut-Down the Computer within your Remaining Back-up Time, it will Automatically Close your all programs and Shut-Down the System so because of proper Shut-Down, your Program & Hard Drive is Safe.

 

Operating System Protection

        Almost all advanced operating  systems  need  user to Shut-Down before turning off the  power, otherwise  the  system might  be  damaged and there  is  no  way  to  start  it unless you re-install the operating system. So a GIRIRAJ Intelligent UPS  Software has to  Shut-Down the system to save the operating system before the UPS runs out of battery power.

GIRIRAJ Intelligent UPS software not only provide this necessary feature, but it also provide File Saving Protection.  

 

File Saving Protection:

       Before  Shutting  Down  the  operating  system, the Software tries to close all open files and save them. This advanced feature can prevent you from losing data and wasting valuable time to re-type them. 

 

Analysis:

        People learn from history. A System Manager needs to receive valuable power history data  information in order to increase the reliability  of  the  power management. For this reason, the software provides  you with  power event logging to optimize management of the power. The log file tells you the time, date, day, year and the  power events viz.  power failed,  power  restored, low battery condition and system shutdown.  You  can  use  it  to  determine  your common power problems in order to plan power use in the most productive way.

 

How the GIRIRAJ Intelligent UPS Software Shutdown Sequence Works!!

When power fails, the following series of events occurs:

  • The UPS detects a power failure and switches to Battery power.

  • The UPS instructs the Software program of the power failure through the serial  cable.

  • The Software logs this event in the event log file, pop up a warning message on the        screen and begins the count down process.

  • When the countdown timer expires, the software starts executing the following   Shut-Down  sequence.

            a) Software informs all the active programs to save data and close Programs.

            b) Software shuts down the operating system.

            c) Software tells the UPS to switch off the battery power.

         At any time  during  the  above  process, if the UPS determines that battery power is Extremely low, it notifies the Software of such event via the serial cable. If the Software receives such a signal it immediately executes the shutdown sequence, regardless of  the status of the count down timer.

APPLICATIONS:

  • Data Processing.

  • Process Control.

  • Telecommunication Systems.

  • Medical Equipments.

  • Instrumentation.

  • LAN Systems.

  • ATM Machines.

  • Satellite Communication Systems.

  • Other Sensitive Equipments.
     

FEATURES:

  • Small in Size.

  • Low Audible Noise.

  • Excellent Dynamic Characteristics.

  • Mosfet Based Technology.

  • Very Low Distortion .

  • High Efficiency.

  • Electric Surge Suppression.

  • Easy Installation.

  • Easy Operation.

  • Constant current, Constant Voltage Battery Charger.

  • Optional Computer Interfacing Facility available.

  • Advanced State of the Art Technology.

  • Quasi Sine Wave in Line-Interactive UPS range of 500Va(I) to 1Kva(I).

  • Pure Sine Wave / Quasi Sine Wave in Line-Interactive UPS range of 1Kva(E) to 3Kva(E).

  • Extended Back up Time.

  • User friendly Front Panel Indications.

  • Wide Input Range.

  • Battery Protection.

  • Built in EVR in all Line-Interactive.

  • Short circuit / over load protected.

Advanced hybrid Technology :
      GIRIRAJ UPS has been designed on advanced hybrid technology which uses SMD chips as well as conventional components to ensure reliable quality & easy serviceability.

Higher Efficiency, Longer Back-up :
      
A 0.3 Amp. no load current in DC side in 500 VA GIRIRAJ UPS makes it as much efficient.

Wide Input Range :
     
The UPS has been designed keeping worst power scenario ever. It can perform well at even 150 volt mains input & gives the similar output up to 270 volt mains input.

Upgradability :
      GIRIRAJ UPSs are upgradeable for different type of applications both in terms of VA rating and Back-up, thus making investments lasting long in future.

Battery Maintenance at its Best :
     
GIRIRAJ UPS provides constant voltage current limited charging for the best life span withdrawal from Battery. This reduces the maintenance cost of system considerably.

|TOP|